Online inquiry
Product

Product

Flue gas emission monitoring devices IN-C90 Price:¥

●Clean flue gas (low dust) with a maximum flue gas temperature of 1000°C.
●The electronics, keypad, and LCD display are assembled in a die-cast aluminum housing.
●Displays 02 and C0e concentration values and outputs 4-20mA.
●Customized ANSI, DIN and other standard flanges, different lengths of deflector pipe, deflector pipe diameter is 60mm.
●The flange has a connection for compressed air.
●The reference gas inlet is on the small flange of the connecting pipe, the diameter of the flange is 100mm.
●The power and signal lines (analog 4-20mA and digital RS-485 communication) are connected with robust industrial plugs.

Online inquiry
Detailed content Specification parameter Product packaging

Technical Parameters

preheating time

min 30 Minutes

measuring range

0.1-25%  VOL-% 02

0-1000ppm C0e (Select to Measure C0e)

accuracy

02: ± 0.2% F.S, or ± 5% reading

C0e: ± 50ppm or ± 10% reading

flange

ANSI flange: 230mm / probe: 60mm, probe up to 4 meters

Or DN80 PN16 flange

Flange temperature

min.+70℃…max.+150℃

(No smoke dew on flange)

The T90 response time

<10 Seconds

analog output

Two road 4-20 mA isolation output

0-25% 02 and 0-1000ppm: linear output

The user can change the range and step down by 0.5%s

numeric output

RS485 Isolation Output (Modbus protocol)

source

18-24Vdc (0CM417),90-100W

100-240Vac,max.100W

cable

special cable

2-wire power supply (0CM 417) + 1-wire (ground wire)

2-wire power supply 100-240 Vac (0CM417RT)

2-line RS485 isolated input and 2-line RS485 isolated output

2-line 4-20 mA 02 analog output

A 2-line 4-20mA C0e analog output

Electronic transmitter

Microprocessor, LCD display, 4 buttons

Check the gas inlet

Check the gas inlet joint: 6 / 4mm trachea

Blow the gas entrance

min.6-8bar Compressed air, quick joint, connected to 8mm trachea

ambient temperature

-20℃- +55℃

hull

Ppressed aluminum housing, 160 * 160 * 160mm, 200mm connecting pipe, 50mm diameter

levels of protection

IP65


Measuring principle

●Oxygen (O2): Zirconia Sensors

●Combustible gas (COe): Solid-state electrolyte sensor

※COe:The sum of combustible gases (CO+H2+Cx+Hy) is considered as CO


Standard Features

●Clean flue gas (low dust) with a maximum flue gas temperature of 1000°C.

●Electronics, pushbuttons, and LCD display are assembled in a die-cast aluminum housing.

●Display of O2 and COe concentration values with 4-20mA output.

●Customized standard flanges such as ANSI, D IN, etc., with different lengths of guide pipes, the diameter of which is 60 mm. The flanges have connections for compressed air.

●The reference gas inlet is on the small flange of the connecting pipe, and the diameter of the flange is 100mm.

The power and signal lines (analog 4-20mA and digital RS-485 communication) are connected with robust industrial plugs.